ConMed 60-8005-001 System 5000 Electrosurgical Generator (ESU), w/ English Panel, 120V (ESU Only)
- Overview
- Accessories
- Customers Also Bought
- Your Recently Viewed Items
- Reviews
Overview
System 5000™ Electrosurgical Generator (ESU)
Uniting technology with versatility.
The System 5000™ Electrosurgery Generator provides the opportunity to fine tune the electrosurgical generator to specific procedure and surgeon preferences. General Mode delivers the full energy performance of CONMED's Dynamic Response Technology, which immediately detects and automatically adjusts to changes in tissue impedance. Other modes include Pulse Coag, Pulse Cut, Micro Bipolar, and Macro Bipolar.
Unique modes on the System 5000™ include the Fluids Mode and Lap Mode. Fluids Mode is used for an additional boost of energy in procedures taking place in a fluid environment. Lap Mode limits open circuit voltages to below 2700 volts in all modalities and reduces the potential risk of inadvertent burns from capacitive coupling.
Clinical Benefits: Reliability, Precision and Patient Safety
Since its introduction, the System 5000™ Electrosurgical Unit (ESU) has become synonymous with safety, performance, precision and reliability. Trusted around the world, the versatility of the System 5000 meets a variety of procedure-specific energy output needs including General, Laparoscopic and Robotic surgery.
Controlled Energy for the Desired Clinical Effect to Tissue
Proprietary Dynamic Response Technology samples the current and voltage 450,000 times per second which enables it to respond to tissue impedance changes in less than 10 milliseconds. This ensures the precise voltage needed is safely delivered to each tissue type.
Reduced Risk of Coupling and Inadvertent Burns Helps Improve Patient Safety
The System 5000's Lap mode provides a unique safety feature that significantly reduces the risk of coupling and inadvertent burns during laparoscopic and robotic surgery by limiting voltage in all monopolar modalities to below 2,700 volts.
Unique Pulse Coag Mode Helps Minimize Blood Loss
With pulsing coagulation energy on and off every 2.5 milliseconds, precise hemostasis with less tissue carbonization than standard coag at equivalent power
settings, is achieved.
Validated for Use With da Vinci Surgical System
Custom energy activation cable allows for seamless activation with the da Vinci S® & Si surgical robotic systems.
Additional Features
- Automatic Return Monitor (ARM®)
- Advanced Specialty Modes (3 Modes)
- 9 Programmable Memory Settings
- Illuminated Accessory Portals
For more information, please see Brochure