Myron L 759II-114 750 Series II Digital 0-100 ppm Conductivity Monitor
- Specification
- Overview
- Accessories
- Customers Also Bought
- Your Recently Viewed Items
- Reviews
Overview
The unique circuitry of the 750 Series II Conductivity Monitor/controllers guarantees accurate and reliable measurements. Drift-free performance is assured by "field proven" electronics, including automatic DC offset compensation and highly accurate drive voltage. Since temperature compensation is at the heart of accurate water measurement, all Myron L Monitor/controllers feature a highly refined and precise TC circuit. This feature perfectly matches the water temperature coefficient as it changes. All models corrected to 25°C. The TC may be disabled to conform with USP requirements.
Built-in electronic calibration allows for fast quality checks without standard solutions. (Note: for maximum system accuracy standard solutions are recommended). A push-to-test button makes setpoint checks easy, while the internal alarm set discourages unauthorized adjustments.
Standard on all controller models is a heavy-duty 10 amp output relay, operating on either increasing or decreasing readings. Bright green/red LEDs indicate above or below setpoint readings. All 750 Series II models feature an IP65/ NEMA 4X water-resistant and corrosion-proof rated enclosure. Compact in size at 152 x 122 mm/6 x 4.8 in., they are suitable for panel, bench or surface mounting.
Additional options include a 3 Sensor Input Switch and/or a 3 Range Switch and a Remote Alarm model RA.
Features
- Conductivity ranges: 0-50000 Microsiemens, 0-50000 ppm, 0-200 mS, 0-200 ppt
- Automatic temperature compensation to 25°C
- Isolated 0-10 VDC Recorder Output standard
- IP65/NEMA 4X water-resistant and corrosion-proof enclosure
- Built-in electronic calibration
- Single set point/alarm standard
- Adjustable setpoint hysteresis
- Solid State 24 VDC Output
- 10 amp relay operates on choice of increasing or decreasing reading
- LEDs show "above/below" Alarm/control status
- Push-to-test set point check
- Internal set point discourages unauthorized adjustment
- Selectable 115/230 VAC
- Reliable, easily installed sensors
Benefits
- Affordable
- Ease of Operation
- Low Maintenance
- Ensures Product Quality
750 Series II Product Applications:
- Reverse Osmosis
- Process Control
- Seawater Desalination
- Waste Treatment
- Food Processing
- Plating
- Power Plants
- Laboratories
- Printing
- Aquaculture
- Agriculture
- Environmental Studies
- Medical
- Boilers (250 psi at 205°C)
- Cooling Towers
750 Series II Sensor Specifications:
- Temperature Compensation: Integral thermistors provide automatic TC to 25°C between 0-100°C/32-212°F.
- Pressure /Temperature Limits: CS51: 100 psi / 690 kPa at 100°C/212°F. 250 psig at 205°C, Models CS40 and CS41 sensors available on special order.
- Bushing: Modular Polypropylene threaded 3/4" NPT. 1/2" PVDF or 316 stainless steel fittings available as option.
- Cable: Shielded 10 ft./3 meters standard 25 and 100 ft./ 8 and 30 meter lengths available. 100 ft./30 meter is maximum recommended.
- Dimensions: CS51: Metal portion 30 L x 13 Dia. mm/ 1.2 L x .5 Dia. in.
Sensors - CS51LC, CS51 and CS52
These reliable sensors feature an integral temperature sensor to ensure accurate and rapid automatic temperature compensation. The sturdy polypropylene bushing is modular for easy inexpensive replacement. Several alternatives for the metal portion of the sensor are available, depending on the demands of the application.
- CS51LC sensors (0.1 constant) are used for 5 and below.
- CS51 sensors (1.0 constant) are used between 0-10 and 0-20,000.
- CS52 sensors (10.0 constant) are used above 20,000.
For more information, please see Data Sheet