GfG Instrumentation 2801-22-001 CC28 Series Fixed Transmitter with Gas Optimized Catalytic Sensor, Benzene, No Display, 0-100% LEL Range

  • Specification
  • Overview
  • Accessories
  • Customers Also Bought
  • Your Recently Viewed Items
  • Reviews
GfG Instrumentation 2801-22-001 CC28 Series Fixed Transmitter with Gas Optimized Catalytic Sensor, Benzene, No Display, 0-100% LEL Range
Click to zoom
  • Regular Price: $1,445.00
Safe Checkout
Fully secured
Money back Guaranty
100% satisfaction

Overview


For flammable gases and vapors in Ex zones

If combustible gases and vapors are to be monitored in Ex zones, the CC28 transmitter is a reliable and economical solution. The CC28 uses an analog (4-20 mA) signal to provide measured values and status information. The special stack effect ensures very short response times of only a few seconds for fast warning of explosion hazards. In combination with GfG's reliable controllers, it can be installed in new gas detection systems or retrofitted into existing ones.

The CC28 uses catalytic combustion (CC) to detect combustible gases and vapours. The long-life sensors make the CC28 an economical solution for detecting Benzene in the measurement range 0-100% LEL. Its automatic temperature compensation and the linearization of the measurement signals ensure high measurement accuracy.

Explosion protection, functional safety and device protection

The CC28 has ATEX certification for use in Ex Zone 1, and its hardware complies with the European Functional Safety Standard DIN EN 61508-2: 2011 (SIL). The housing is protected against ingress of dust and water (protection class: IP64).

Communication and service

Signals are transmitted via the analog industry standard (4-20 mA). The CC28 uses two status LEDs to indicate its operating status. Service and adjustments are carried out on site using the optional RC2 remote control (one-man adjustment). The pre-adjusted sensors can be easily replaced thanks to Smart Sensor technology. Test gases for function tests can be inserted using a flow adapter.

Features:

  • Measurement method: Catalytic combustion (CC)
  • Measurement gas: Benzene
  • Short response time due to stack effect
  • Expected sensor lifetime: 5 years
  • Signal transmission: 4-20 mA
  • Protection class: IP64
  • Sensor MK 208-1

Approvals / Certifications:

  • ATEX certification: II 2G Ex demb [ib] IIC T4 Gb
  • SIL 2/3 (hardware)